<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T20:21:29Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/11779" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/11779</identifier><datestamp>2025-03-26T23:34:16Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9908</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Kulic, Dana</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="230db05e-d23e-4f03-bd3b-9e4884f2a979" confidence="600">Kianifar, Rezvan</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2017-04-28T14:22:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2018-04-29T04:50:08Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2017-04-28</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2017-04-26</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/11779</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Many clinical assessment protocols rely on the evaluation of functional movement tests&#xd;
such as the Single Leg Squat (SLS), which are often assessed visually. Visual assessment&#xd;
is subjective and depends on the experience of the clinician. Developing a reliable automatic&#xd;
human motion tracking and assessment system can improve the accuracy of SLS&#xd;
clinical assessments and provide objective results that can be tracked and monitored over&#xd;
time to guide rehabilitation and determine an individual&amp;apos;s response to an intervention.&#xd;
In this study, an Inertial Measurement Unit (IMU) based method for automated assessment&#xd;
of squat quality is proposed to provide clinicians with a quantitative measure of SLS&#xd;
performance.&#xd;
First, an automated pose estimation method is applied to SLS motion data. A set&#xd;
of three IMUs is used to estimate the joint angles, velocities and accelerations of the&#xd;
squatting leg. To tackle noisy sensor measurements and gyro drift, a 7 degree of freedom&#xd;
(DOF) kinematic model of the lower leg was applied together with a constant acceleration&#xd;
assumption to approximate the angular velocity and linear acceleration at each sensor&#xd;
location. The kinematic model predictions of the angular velocity and linear acceleration&#xd;
and sensor measurements were fused via an Extended Kalman Filter (EKF). The position,&#xd;
velocity, and acceleration of each DOF were defined as the states to be estimated by&#xd;
the EKF. The pose estimation results showed successful extraction of joint angles with&#xd;
an average RMS error of 3.2 degrees, 5.5 degrees, 7 degrees compared to joint angles estimated from motion&#xd;
capture for the ankle, knee, and hip joints, respectively. For this estimation, the required&#xd;
parameters for the kinematic model, including information about the sensor placement and&#xd;
orientation as well as the kinematic link lengths, were extracted from the marker data.&#xd;
However, in clinical applications of the proposed method, when marker data is not&#xd;
available, these parameters need to be measured. Measuring these parameters is time consuming&#xd;
in the clinical setting, which limits application of IMUs for clinical purposes. With&#xd;
the motivation to make this procedure easier and faster, a method for approximating the&#xd;
parameters using placement assumptions and body measures was described. A sensitivity&#xd;
analysis was performed to detect those parameters which most affect pose estimation accuracy.&#xd;
The sensitivity analysis results revealed that sensor orientation is the most critical&#xd;
factor for accurate pose estimation. In this thesis, a simple and easy to use method is&#xd;
proposed for sensor orientation calibration, based on a systematic placement of sensors&#xd;
and using gyroscope information for orientation estimation. This protocol was evaluated&#xd;
experimentally and pose estimation error with approximated parameters before and after&#xd;
applying the calibration protocol were compared. The comparison results showed that the&#xd;
estimate of the sensor orientation increases the pose estimation accuracy by 6.5 degrees for the&#xd;
knee joint angle and with an average of 1.8 degrees for other joints without the need for time&#xd;
consuming calibration.&#xd;
In the second part of the thesis, an algorithm for automated assessment of the SLS&#xd;
in terms of dynamic knee valgus and risk of knee injury is developed. After applying the&#xd;
pose estimation algorithm to IMU data of SLS motions, the estimated time series data&#xd;
of joint angles, velocities and accelerations for consecutive squats were segmented into&#xd;
individual squat repetitions. Statistical time domain features were generated from each&#xd;
repetition. The most informative features were selected using a combination of 18 feature&#xd;
selection techniques. Six common classifiers in including SVM, Linear Multinomial Logistic&#xd;
Regression, Decision Tree, Naive Bayes, K Nearest Neighborhood, and Random Forests&#xd;
were applied to the full dimensional data, the subset of selected features, and extracted&#xd;
features by supervised principal component analysis. The proposed approach was evaluated&#xd;
in two trials. First, a pilot study was conducted on a small dataset, followed by analysis&#xd;
on a larger clinical data set, collected by our clinical collaborator. For the clinical study, a&#xd;
dataset of SLS performed by healthy participants was collected and labelled by three expert&#xd;
clinical raters using two different labeling criteria: &amp;quot;observed amount of knee valgus&amp;quot; and&#xd;
&amp;quot;overall risk of injury&amp;quot;. Labels included &amp;quot;good&amp;quot;, &amp;quot;moderate&amp;quot;, and &amp;quot;poor&amp;quot; squat quality&#xd;
or &amp;quot;high risk&amp;quot;, &amp;quot;mild to moderate risk&amp;quot;, and &amp;quot;no risk&amp;quot; of injury. Feature selection results&#xd;
showed that both flexion at the hip and knee, as well as hip and ankle internal rotation&#xd;
are discriminative features, and that participants with &amp;quot;poor&amp;quot; squats bend the hip and&#xd;
knee less than those with better squat performance. Furthermore, improved classifi cation&#xd;
performance was achieved by training separate classifi ers strati ed by gender. Classifi cation&#xd;
results showed excellent accuracy, 93.1% for classifying squat quality as &amp;quot;poor&amp;quot; or &amp;quot;good&amp;quot;&#xd;
and 95.3% for differentiating between high and no risk of injury.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Human Pose Estimation</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Single Leg Squat</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Inertial Measurement Unit</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Classification</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Risk of Knee Injury Assessment</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Dynamic Knee Valgus Assessment</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Automated Pose Estimation for the Assessment of Dynamic Knee Valgus and Risk of Knee Injury during the Single Leg Squat</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="discipline" lang="en">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="grantor" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws-etd" element="embargo" qualifier="terms" lang="en">1 year</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="advisor">Kulic, Dana</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="affiliation1" lang="en">Faculty of Engineering</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="city" lang="en">Waterloo</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="country" lang="en">Canada</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="province" lang="en">Ontario</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>