<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T21:35:59Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/15920" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/15920</identifier><datestamp>2025-03-26T23:31:52Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9912</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Yeow, John</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="42d4486d-ca17-42ef-b81e-859b50540e5d" confidence="600">Owais, Tirad</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2020-05-26T19:12:51Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2020-05-26T19:12:51Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2020-05-26</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2020-05-14</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/15920</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">The need for using ultrasound non-destructive testing (NDT) to characterize, test and detect flaws within metals, led us to utilize Capacitive Micromachined Ultrasound Transducers (CMUTs) in the ultrasound NDT field. This is due to CMUT&amp;apos;s large bandwidths and high receive sensitivity, to be a suitable substitute for piezoelectric (PZT) transducers in NDT applications.&#xd;
The basic operational test of CMUTs, conducted in this research, was carried out based on a pulse-echo technique by propagating acoustic pulses into an object and analyzing the reflected signals. Thus, characterizing the tested material, measuring its dimension, and detecting flaws within it can be achieved.&#xd;
Throughout the course of this research, the fundamental parameters of CMUT including pull-in voltage and resonance frequency were initially calculated analytically and using Finite Element Analysis (FEA). Afterward, the CMUT was fabricated out of two mechanically bonded wafers. The device&amp;apos;s movable membrane (top electrode) and stationary electrode (bottom electrode) were made out of Boron-doped Silicon. The two electrodes were electrically isolated by an insulation layer containing a sealed gap.&#xd;
The CMUT was then tested and characterized to analyze its performance for NDT applications. In-immersion characterization revealed that the 2.22 MHz CMUT obtained a -6 dB fractional bandwidth of 189%, and a receive sensitivity of 31.15 mV/kPa, compared to 45% and 4.83 mV/kPa of the PZT probe. A pulse-echo test, performed to examine an aluminum block with and without flaws, showed success in distinguishing the surfaces and the flaws of the tested sample.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">CMUT</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">NDT ultrasound</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Capacitive Micromachined Ultrasound Transducers for Non-Destructive Testing Applications</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Mechanical and Mechatronics Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="discipline" lang="en">Mechanical Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="grantor" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="advisor">Yeow, John</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="affiliation1" lang="en">Faculty of Engineering</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="city" lang="en">Waterloo</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="country" lang="en">Canada</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="province" lang="en">Ontario</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>