<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-23T04:56:25Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/18193" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/18193</identifier><datestamp>2025-03-26T23:36:09Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9906</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Hansson, Carolyn</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="a428e782-b010-407b-8db3-b45fcfec7bd2" confidence="600">Yang, Fook Yee</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2022-04-29T12:52:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2022-04-29T12:52:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2022-04-29</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2022-04-17</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/18193</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">During the winter season, ice accumulation on roads and sidewalks is a major problem and &#xd;
poses a hazard to road users. The most common method of addressing this issue is by applying &#xd;
de-icing salts or spraying a brine solution on road surfaces. Unfortunately, the use of de-icing &#xd;
salts and anti-icing brines has a detrimental effect on concrete infrastructure by causing &#xd;
corrosion of steel reinforcement and deterioration of the concrete matrix. &#xd;
The issue of corrosion can be addressed by using more corrosion resistant material as &#xd;
reinforcement (rebar), such as stainless steel. Currently, the manufacturing process of stainless &#xd;
steel rebar involves a hot rolling process followed by shotblasting to remove mill scale formed &#xd;
during the high temperature rolling process and then acid pickling to remove the chromium &#xd;
depleted layer below the mill scale. Since this process is generally required by many authorities, &#xd;
there is little literature on the effect of mill scale on the corrosion resistance of stainless steel.  &#xd;
The main goal for this project is to determine the effect of surface condition due to post-rolling &#xd;
processes on the corrosion performance of UNS 32205 duplex stainless steel rebar. &#xd;
Furthermore, this project examines the condition of the mill scale after exposure to the high pH &#xd;
environment in concrete for an extended time. Four different surface conditions of rebar were &#xd;
tested as part of this project: as-rolled (no treatment), shotblasted-only, pickled-only, and both &#xd;
shotblasted-and-pickled.  &#xd;
This project is divided into three parts: rebar surface characterization, a rapid corrosion &#xd;
screening test, and a longer-term corrosion exposure test. Firstly, surface characterization was &#xd;
carried out by optical microscopy, scanning electron microscope (SEM) paired with energy-dispersive&#xd;
X-ray spectroscopy (EDX), and secondary ion mass spectrometry (SIMS).  &#xd;
The rapid screening test provides only a qualitative comparison of the corrosion resistance. For &#xd;
this test, six replicate lengths of rebar of each type of surface condition were cast into concrete &#xd;
cylinders. Sodium chloride was dissolved in the mixing water to induce active corrosion. The &#xd;
concrete cylinders were cured for 24 hours before being demoulded and immersed in saturated &#xd;
calcium hydroxide solution. The open circuit potential of the bars was monitored for 24 hours; after which, they were anodically polarized for 96 hours. The current response in the rebar was &#xd;
recorded during this time. Only two of the 30 specimens exhibited active corrosion during the &#xd;
96 hours of polarization. These were two of the six shotblasted-only bars. There are several &#xd;
possible reasons for the corrosion found in only these bars. Firstly, the shotblasting process was &#xd;
done using carbon steel chips as a medium. Any embedded carbon steel in the mill scale would &#xd;
be more susceptible to corrosion. Secondly, microscopy showed incomplete removal of mill &#xd;
scale from these bars. This would lead to a galvanic effect between areas with mill scale &#xd;
remaining and areas where mill scale had been removed, further aggravating any corrosion. &#xd;
The as-rolled and pickled-only bars exhibited similar corrosion rates to those which were fully &#xd;
treated, i.e., shotblasted-and-pickled bars. This was unexpected because the mill scale was &#xd;
cracked in many places and still had a chromium depleted layer in the underlying steel. These &#xd;
results show that, at least in this test, as-rolled UNS 32205 rebar performs as well as those with &#xd;
conventional post-rolling treatments.   &#xd;
For more quantitative data, a modified version of the ASTM A955 macrocell corrosion test was &#xd;
used. In this test, rebar specimens were cast in concrete mortar rectangular blocks with a &#xd;
ponding well. Four replicates of each surface condition were prepared. Saturated calcium &#xd;
hydroxide was added to the ponding well to prevent calcium hydroxide from leaching out and &#xd;
maintaining a high pH environment. After 200 days, 15% sodium chloride solution was added to &#xd;
the ponding well of three replicates in an attempt to initiate corrosion. One replicate of each &#xd;
surface condition was kept without exposure to chlorides to allow observation of the effect of &#xd;
the high pH on the mill scale.  Throughout this time, the macrocell potential of the bar was &#xd;
measured. Electrochemical tests were performed periodically to monitor for any corrosion &#xd;
activity. After 440 days, two of the three replicates exposed to chlorides were autopsied to &#xd;
examine the condition of the rebar. None of the bars exhibited active corrosion rates and there &#xd;
were no visible signs of corrosion on the autopsied bars.  It was concluded from this test that a &#xd;
15% sodium chloride solution is insufficient to initiate corrosion in UNS 32205 rebar in any of &#xd;
the surface conditions.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">corrosion</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">stainless steel</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">mill scale</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">concrete</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">reinforcing bars</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">oxide layer</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Effect of Post-Rolling Surface Condition on the Corrosion Performance of UNS 32205 Stainless Steel Rebar</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Civil and Environmental Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="discipline" lang="en">Civil Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="grantor" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws-etd" element="embargo" qualifier="terms" lang="en">0</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="advisor">Hansson, Carolyn</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="affiliation1" lang="en">Faculty of Engineering</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="city" lang="en">Waterloo</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="country" lang="en">Canada</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="province" lang="en">Ontario</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>