<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T22:37:50Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/18984" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/18984</identifier><datestamp>2025-03-26T23:37:53Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9912</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Chandrashekar, Naveen</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="16c519f6-f032-4027-a457-3b0fb8ce40d2" confidence="600">Gupta, Pratishtha</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2022-12-21T20:03:04Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2023-12-22T05:50:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2022-12-21</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2022-12-16</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/18984</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Injury and musculoskeletal diseases in the knee due to excessive loading at the ligaments&#xd;
can cause mechanical instability to the joint. Knee bracing has been commonly used to&#xd;
support and provide external stabilization to the joint by restraining its motion and redistributing&#xd;
loads acting on the ligaments. Several studies have been conducted to quantify&#xd;
the effectiveness of knee braces in ligament injury prevention during static and quasi-static&#xd;
loading conditions. However, studies to assess them in dynamic loading conditions remain&#xd;
limited.&#xd;
&#xd;
The aim of this study was to determine the effects of the mechanical design of the&#xd;
Stoko K1 knee brace on the strain behaviour of the Anterior Cruciate Ligament (ACL)&#xd;
in dynamic loading conditions computationally using Finite Element (FE) analysis. The&#xd;
Stoko knee brace evaluated in the current study utilizes a compliant design that has a&#xd;
system of non-extensible pre- tensioned cables running through a compression tight along&#xd;
designed pathways to stabilize the knee mechanics. An FE model of the knee brace was&#xd;
developed on an existing FE model of a knee. The FE model was validated in quasi-static&#xd;
varus/valgus loading conditions by comparing the effective load reduction at the knee to&#xd;
experimental test data available. Single-leg jump landing simulations were then conducted&#xd;
in braced configuration by inputting the muscle forces and joint kinematic/kinetic profiles&#xd;
for ten participants. ACL strain behaviours for post-ground contact duration of 200ms&#xd;
were compared between braced and unbraced configurations to assess the efficacy of knee&#xd;
brace in reducing ligament injury.&#xd;
&#xd;
The results showed that the effective load at the knee reduced with the brace compared&#xd;
to without the brace during quasi-static varus/valgus loading, similar to the experimental&#xd;
results. Load reduction in braced configuration compared to unbraced configuration was&#xd;
4.15% during valgus and 29.3% during varus loading condition. During the jump-landing&#xd;
activity, the mean ACL strain in braced configuration increased to 6.59 ±2.41% from 5.54&#xd;
±2.41% (p = 0.024) in unbraced configuration. The mean time taken for ACL to peak&#xd;
decreased from 80.66 ±27.14 ms in unbraced configuration to 61.33 ±24.61 ms (p = 0.007)&#xd;
in braced configuration. It was concluded that the mechanical design of the knee brace&#xd;
could cause the ACL strain to increase during dynamic loading. However, further studies&#xd;
are necessary to evaluate the changes in muscle firing patterns in the braced configuration,&#xd;
their effect on ACL strain behaviour and the effect of knee brace on other knee ligaments&#xd;
such as the Medial Collateral Ligament and Lateral Collateral Ligament.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Knee Brace</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Single-Leg Jump Landing</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Anterior Cruciate Ligament</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Computational Analysis to Evaluate the Effects of Knee Brace on Anterior Cruciate Ligament during Single-Leg Jump Landing</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Mechanical and Mechatronics Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="discipline" lang="en">Mechanical Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="grantor" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws-etd" element="embargo" qualifier="terms" lang="en">1 year</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="advisor">Chandrashekar, Naveen</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="affiliation1" lang="en">Faculty of Engineering</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="city" lang="en">Waterloo</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="country" lang="en">Canada</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="province" lang="en">Ontario</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>