<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-23T07:11:07Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/20661" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/20661</identifier><datestamp>2025-03-26T23:35:20Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9908</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Wang, Zhou</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="34b63e61-65ce-4689-9e8d-8abca8b5e75a" confidence="600">Wang, Zhongling</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2024-06-18T14:51:14Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2024-06-18T14:51:14Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2024-06-18</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2024-05-31</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/20661</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">In the rapidly evolving field of general digital imaging and whole slide imaging, Image&#xd;
Quality Assessment (IQA) plays a crucial role in determining the perceptual quality of&#xd;
images and guiding image restoration. State-of-the-art IQA models are computationally&#xd;
expensive due to the use of complex deep learning architectures. The high computational&#xd;
cost poses a significant challenge in high-throughput Whole Slide Image (WSI) scanning&#xd;
platforms, which is both time-sensitive and power-limited. Moreover, most IQA models,&#xd;
while varied in design, often exhibit biases towards specific types of image content or dis-&#xd;
tortions, a consequence of their underlying design principles or training data. To improve&#xd;
the quality of WSIs, we need to address the defocus problem, which is the most common&#xd;
distortion for a WSI. The transparency and uneven surface of tissue samples further com-&#xd;
plicate the restoration process for methods that lack an understanding of the 3D tissue&#xd;
radiance. These issues emphasize the limitations and challenges faced by existing IQA and&#xd;
restoration models. This thesis proposes three novel and flexible approaches to mitigate&#xd;
these problems.&#xd;
&#xd;
Addressing the efficiency concerns in whole slide imaging, this thesis presents a highly&#xd;
efficient model for Focus Quality Assessment (FQA). Among the distortions that degrade&#xd;
the quality of digital slides, out-of-focus blur is the most common one. Different from pho-&#xd;
tographic images, WSIs have much bigger dimensions, making most deep-learning based&#xd;
FQA models computationally infeasible. Based on prior knowledge of the WSI and its&#xd;
imaging process, we developed a lightweight model named FocusLiteNN that is 10, 000&#xd;
times more efficient than SOTA deep learning-based ones without compromising accu-&#xd;
racy. Furthermore, we introduce the first open-source, expert annotated FQA dataset&#xd;
TCGA@Focus, offering a comprehensive platform for developing and evaluating new FQA&#xd;
models.&#xd;
&#xd;
However, most FQA models, or IQA models in general, often exhibit biases towards&#xd;
specific types of image content or distortions due to their different design principles or&#xd;
training data. This poses a challenge for users when choosing the best quality assessment&#xd;
model for their needs. A practical approach is to fuse the results of multiple existing IQA&#xd;
models into a more robust one. Following this idea, we developed a novel framework for IQA core fusion that is able to select the best combination of models according to the&#xd;
uncertainty in each image and the overall uncertainty of each model. This requires the&#xd;
model to be equipped with both fine-grained uncertainty analysis at the content level and&#xd;
coarse-grained uncertainty analysis at the model level, respectively. Existing models either&#xd;
lack content-level uncertainty estimation or have limited generalizability due to supervised&#xd;
training. Our method employs an unsupervised approach using deep Maximum a Posteriori&#xd;
(MAP) estimation, which can be trained on a combination of multiple datasets without&#xd;
the need for Mean Opinion Score (MOS). This greatly improves the generalizability of the&#xd;
model.&#xd;
&#xd;
The above two works address different problems in quality assessment. In practice,&#xd;
detected bad-quality images are either rejected or recollected. In digital pathology, rec-&#xd;
ollecting the biosample causes additional suffering for the patient. Consequently, defocus&#xd;
restoration is a possible solution. Deblurring assumes that there exists a sharp image in&#xd;
which all pixels are in-focus, which is commonly referred to as a All-In-Focus (AIF) image.&#xd;
Although this assumption is true for natural images, it might not hold for WSIs due to its&#xd;
transparency, uneven surface and the microscope’s shallow Depth of Field (DOF). Since&#xd;
the target does not exist, WSI deblurring becomes an undefined task. We propose an&#xd;
alternative approach to address the defocus problem, which is virtual refocusing. It aims&#xd;
to simulate and surpass the traditional experience of one continuously adjusting the focus&#xd;
of a microscope, allowing for a comprehensive examination of tissue structures at varying&#xd;
depths without the need for physical slide presence. By implicitly learning a continuous&#xd;
3D radiance representation from the sparse inputs, the proposed model can refocus each&#xd;
pixel to any focus plane according to a focus map. As far as we know, this is the first work&#xd;
on WSI virtual refocusing.&#xd;
&#xd;
This thesis makes significant contributions to IQA and image restoration with applica-&#xd;
tions in WSI. The introduction of the FocusLiteNN model boosts computational efficiency&#xd;
while the score fusion model addresses the bias issue. Additionally, the virtual refocusing&#xd;
model extends these improvements by tackling the defocus problem in WSI through precise&#xd;
adjustment of focus on a per-pixel basis.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">image quality assessment</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">whole slide image</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">image refocus</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">score fusion</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">focus quality assessment</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">image deblur</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">digital pathology</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Image Quality Assessment and Refocusing with Applications in Whole Slide Imaging</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Doctoral Thesis</dim:field>
   <dim:field mdschema="dc" element="pending">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="discipline" lang="en">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="grantor" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Doctor of Philosophy</dim:field>
   <dim:field mdschema="uws-etd" element="embargo" qualifier="terms" lang="en">0</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="advisor">Wang, Zhou</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="affiliation1" lang="en">Faculty of Engineering</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="city" lang="en">Waterloo</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="country" lang="en">Canada</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="province" lang="en">Ontario</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>