<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-23T04:24:30Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/23361" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/23361</identifier><datestamp>2026-05-21T13:31:19Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9908</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Loka, Rino</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-05-21T13:31:19Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-05-21T13:31:19Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026-05-21</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2026-05-06</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10012/23361</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Continuous glucose monitoring (CGM) can improve diabetes management by providing frequent measurements and revealing trends that are difficult to capture with invasive, intermittent tests. To this end, a miniaturized, wearable sensing platform that operates continuously and delivers timely alerts is beneficial for individuals who require active glucose management.

This thesis presents a wireless transmitter, implemented in a complementary metal-oxide-semiconductor (CMOS) integrated circuit technology, for energy-efficient telemetry of biomedical signals from a wearable device that transmits short packets to a smartphone, enabling practical daily readout. Since the transmitter must meet Bluetooth Low Energy (BLE) constraints under a tight energy budget, several circuit and system-level design choices that balance frequency accuracy, spectral compliance, and robustness to process-voltage-temperature (PVT) variation at low supply voltages must be made.

The proposed wireless transmitter is one component of a larger mixed-signal system-on-chip (SoC), which integrates a commercially-available electrochemical sensor that interacts with glucose and/or ketones, to enable continuous concentration measurement. The sensing front-end electronics of the SoC converts chemical activity into an electrical signal that is conditioned and digitized on-chip. This measured concentration is then encoded for BLE-compatible transmission by modulating the digitized data using Gaussian frequency-shift keying (GFSK) in the 2.4 GHz industrial, scientific, and medical (ISM) band, implemented as an integer-N charge-pump phase-locked loop (CP-PLL) with direct voltage-controlled oscillator (VCO) modulation.

Simulated and experimental results from a fabricated prototype chip demonstrate the feasibility of the proposed approach in terms of sensor readout, burst energy, and BLE spectral compliance. Implemented in a 0.18 µm bulk CMOS process, the fabricated transmitter delivers -7.06 dBm at 13.5 mW DC power, with an intra-packet drift of 41.56 kHz and reference spurs of −26.4 dBm at ±2 MHz offsets — both within BLE LE 1M limits. End-to-end validation confirms the successful reception of BLE advertising packets on a commodity Nordic nRF5340 receiver, with the digitized electrochemical sensor data reconstructed from over-the-air stream. The presented methodology provides a foundation for compact wearable bio-sensing platforms, combining continuous chemical sensing with standardized wireless communication for patient-facing monitoring and alerts.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject">ble advertising cmos transmitter</dim:field>
   <dim:field mdschema="dc" element="subject">bluetooth low power</dim:field>
   <dim:field mdschema="dc" element="subject">continuous glucose mentoring  (CGM)</dim:field>
   <dim:field mdschema="dc" element="subject">integer-N pll for BLE</dim:field>
   <dim:field mdschema="dc" element="title">A Low-Power Wireless Transmitter for a Continuous Glucose Monitoring System-on-Chip</dim:field>
   <dim:field mdschema="dc" element="type">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="discipline">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="grantor" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="uws-etd" element="degree">Master of Applied Science</dim:field>
   <dim:field mdschema="uws-etd" element="embargo" qualifier="terms">2 years</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="advisor">Levine, Peter</dim:field>
   <dim:field mdschema="uws" element="contributor" qualifier="affiliation1">Faculty of Engineering</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="city" lang="en">Waterloo</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="country" lang="en">Canada</dim:field>
   <dim:field mdschema="uws" element="published" qualifier="province" lang="en">Ontario</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">embargo</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>