<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T18:13:09Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/2793" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/2793</identifier><datestamp>2017-03-21T19:17:43Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9908</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en" authority="186fe281-0ddf-44f1-8fc5-a5b2d63de28a" confidence="600">Gabran, Salam Ramy</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-05-08T13:19:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-05-08T13:19:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/2793</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Monitoring bio-electric events is a common procedure, which provides medical data required in clinical and  research applications.   Electrophysiological measurements are applied in diagnosis as well as evaluation of the  performance of different body organs and systems, e.  g.   the heart, muscles and the nervous system.   Furthermore,  it is staple feature in operation rooms and extensive care units.   The performance of the recording system is  affected by the tools and instrumentation used and the bio-electrode is a key-player in electrophysiology, hence,  the improvements in the electrode recording technique will be directly reflected in the system?s performance in  terms of the signal quality, recording duration as well as patient comfort.   In this thesis, a design methodology for micro-spike array dry bio-electrodes is introduced.     &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;  The purpose of this methodology is to meet the design specifications for portable long-term EEG recording and  optimize the electrical performance of the electrodes by maximizing the electrode-skin contact surface area,  while fulfilling design constraints including mechanical, physiological and economical limitations.   This was  followed by proposing a low cost fabrication technique to implement the electrodes.   The proposed electrode  design has a potential impact in enhancing the performance of the current recording systems, and also suits  portable monitoring and long term recording devices.   The design process was aided by using a software design  and optimization tool, which was specifically created for this application.    &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;  The application conditions added challenges to the electrode design in order to meet the required  performance requirements.   On the other hand, the required design specifications are not fulfilled in the current  electrode technologies which are designed and customized only for short term clinical recordings.    &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;  The electrode theory of application was verified using an experimental setup for an electrochemical  cell, but the overall performance including measuring the electrode impedance is awaiting a clinical trial.</dim:field>
   <dim:field mdschema="dc" element="format" lang="en">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">2925922 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en">Copyright: 2006, &#xd;
  Gabran, Salam. All rights reserved.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Electrical &amp;amp; Computer Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">bio-electrodes</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">EEG</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">mems</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">microfabrication</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Design and Optimization Methodology of Sub-dermal&#xd;
Electroencephalography Dry Spike-Array Electrode</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>