<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T17:18:52Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/2862" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/2862</identifier><datestamp>2017-03-21T19:32:18Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9906</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en" authority="94eb0db7-9b27-4a84-9463-d7bd551afdc6" confidence="600">McAllister, Lawrence Brett</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-05-08T13:47:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-05-08T13:47:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/2862</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">The main goal of a drinking water treatment plant is to provide safe drinking water for its  consumers.   Historically, this was accomplished through monitoring the influent and effluent  water quality to ensure that the water quality met a set of guidelines and regulations.   However,  as the limitations of relying on compliance monitoring become more evident, water utilities and drinking water treatment plants are beginning to utilize risk management frameworks to help provide safe drinking water and to mitigate potential risks.   Applying a risk management framework requires an evaluation of potential risks.   This systematic evaluation can be performed through using risk analysis methods.    &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;    
     The overall goal of this research is to analyze and evaluate risk analysis methodologies that are  used in a variety of engineering fields, select two risk analysis methods, and use them to evaluate the probability of producing non-compliant drinking water from a rapid gravity filtration unit with respect to turbidity.    &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;    
     The risk analysis methodologies that were used in this research were the consequence frequency  assessment and computer modelling combined with probabilistic risk analysis.   Both of the risk  analysis methodologies were able to determine the probability of producing non-compliant water  from a rapid gravity filtration unit with respect to turbidity.   However, these methodologies were found to provide different numerical results with respect to each other.   The consequence frequency assessment methodology was found to be easier to implement; however, the  consequence frequency assessment was only able to be performed on one parameter at a time.   Computer modelling and probabilistic risk analysis enabled the inclusion of multiple parameters which provided a more comprehensive understanding of the filtration unit.    &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;    
     The primary conclusion from this research is that the risk analysis methods, as they are described in this thesis, are not sufficient to use directly on a rapid gravity filtration unit without further modification.   Furthermore, although the risk analysis methods provided some guidance, these methods should only be used as a part of a complete risk management process.</dim:field>
   <dim:field mdschema="dc" element="format" lang="en">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">4109835 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en">Copyright: 2006, 
  McAllister, Lawrence Brett. All rights reserved.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Civil &amp;amp; Environmental Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Risk Analysis</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Filtration</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">The Use of Risk Analysis Techniques to Determine the
Probability of Producing Non-Compliant Drinking
Water: Focusing on Dual Media Rapid Gravity
Filtration</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Civil Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>