<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T15:05:58Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/4555" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/4555</identifier><datestamp>2017-03-21T21:31:02Z</datestamp><setSpec>com_10012_9936</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9941</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="f393ea63-d040-410e-b12a-d1a0c6ac153b" confidence="600">Rahimi, Mohammad Mehdi</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-08-17T19:47:31Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-08-17T19:47:31Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2009-08-17T19:47:31Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2009-08-05</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/4555</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">In this thesis, cyclic biamperometry (CB) as a new method in electrochemistry,&#xd;
has been introduced and investigated. The hallmark of this method is the absence&#xd;
of a reference electrode which potentially allows simplification and miniaturization&#xd;
of the measurement apparatus. Similarities and  differences of this method and&#xd;
cyclic voltammetry (CV) have been studied and it was shown that under conditions&#xd;
of using standard electrodes, CB has a better sensitivity and a lower detection&#xd;
limit than CV. A new equivalent circuit model for the cell has been proposed and&#xd;
parameters  affecting the sensitivity of CB, such as keeping the concentration of&#xd;
one redox species in excess and having a larger W2 electrode, have been described.&#xd;
The redox cycling effect in biamperometric systems has been investigated and it&#xd;
is shown that improvements of at least two orders of magnitude in sensitivity can&#xd;
be achieved by using interdigitated electrodes (IDEs). In addition, an example&#xd;
for applications of this method, including biamperometric dead-stop titration of&#xd;
1-naphthol with ferricyanide, has been presented and possible  fields in which CB can&#xd;
be incorporated (e.g. monitoring the activity of alkaline phosphatase) have been&#xd;
illustrated. Finally, a few suggestions for future studies and further improvements&#xd;
have been outlined.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Electrochemistry</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Cyclic voltammetry</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Electroanalytical Chemistry</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Bioanalytical Chemistry</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Chemistry</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Cyclic Biamperometry</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Chemistry</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>