<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T14:19:04Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/5213" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/5213</identifier><datestamp>2017-03-21T21:28:55Z</datestamp><setSpec>com_10012_9915</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9921</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="6fefe743-7846-442f-a87a-8eeeea4925d1" confidence="600">McIsaac, Gerald</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-05-20T16:53:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-05-20T16:53:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2010-05-20T16:53:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2010-05-18</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/5213</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">The use of time domain reflectometry (TDR) to determine water content (θv) from the&#xd;
measurement of the apparent dielectric constant (Ka) or the square root of the apparent dielectric&#xd;
constant (Ka&#xd;
0.5) in highly saline environments has been limited due to the dampening effect that&#xd;
electrical conductivity (EC) has on the TDR signal. The objective of this research was to evaluate the&#xd;
use of a three-rod TDR probe with a polyolefin coating on the center-conducting rod (CCRC probe)&#xd;
to simultaneously measure θv and EC in saline conditions where standard, non-coated TDR probes&#xd;
(NC probe) are ineffective.&#xd;
The application of a 0.00053 m thick polyolefin coating on the center-conducting rod of a CS605&#xd;
TDR probe increased the capability of the probe to measure θv at EC levels as high as 1.06 S m-1&#xd;
compared to 0.132 S m-1 for a NC CS605 probe. The CCRC probe was found to be incapable of&#xd;
determining any difference in EC levels. A 0.01 m long section or “gap” at the center of the&#xd;
polyolefin coating on the center conducting rod (GAP probe) was cut from the polyolefin coating to&#xd;
expose a section of the stainless steel center-conducting rod to allow direct contact with the material&#xd;
being sampled. The GAP probe was found to be capable of measuring θv and EC at EC levels as high&#xd;
as 0.558 S m-1.&#xd;
Using a water-air immersion method, a comparison between the NC probe and the CCRC and&#xd;
GAP probes was undertaken. The correlation between θv vs. Ka&#xd;
0.5 was found to be linear for all three&#xd;
probes with the slope (m) of the regressed equation for the NC probe (m = 7.71) being approximately&#xd;
twice that of the CCRC probe (m = 4.25) and the GAP probe (m = 4.36). The intercept values were&#xd;
equivalent for all three probes. The linearity between θv vs. Ka&#xd;
0.5 for the NC and CCRC probes using&#xd;
the water-air immersion method was also observed when the probes were used to measure Ka&#xd;
0.5 of&#xd;
different sand-water mixtures. The slope of regressed equation for the NC probe in the sand-water&#xd;
iv&#xd;
mixtures (m = 7.69) was equivalent to the water-air immersion slope for the NC probe, however the&#xd;
intercept values for the sand-water mixtures was lower than the intercept values for the water-air&#xd;
immersion method. Similarly, the slope of the CCRC probe in the sand-water mixtures (m = 5.00)&#xd;
was equivalent to the CCRC probe water-air immersion slope. Calculated Ka&#xd;
0.5 values using a waterair&#xd;
dielectric-mixing model (WAMM) were equivalent to measured Ka&#xd;
0.5 values for the NC probe.&#xd;
The water air immersion method was found to provide a suitable methodology for TDR research,&#xd;
however a more definitive test of the coated probe response in a series of soils with a range of&#xd;
homogenous water contents should be completed to ascertain the reliability of the water-air&#xd;
immersion method.&#xd;
The straightforward relationship between the inverse of TDR measured impedance (ZL&#xd;
-1) and EC&#xd;
provided an effective calibration method for both the NC and GAP probes. The use of the Giese-&#xd;
Tiemann method to establish a calibration curve for EC measurement was limited to a maximum EC&#xd;
level of 0.132 S m-1 for the NC probe. The use of the cell constant method was considered to be&#xd;
unacceptable as a means of developing a calibration curve due to the fact that the cell constant K was&#xd;
not a constant value.&#xd;
Ka&#xd;
0.5 values for the CCRC and GAP were consistently less than Ka&#xd;
0.5 values for the NC probe&#xd;
at all qv levels except θv = 0.000 m3 m-3 or 100% air. The difference in Ka&#xd;
0.5 (DKa&#xd;
0.5) between the NC&#xd;
probe and the CCRC and GAP probes was seen to increase with increasing water content. Similarly, a&#xd;
measurable effect was found between the TDR waveforms for the NC probe when the probe head was&#xd;
surrounded completely by air when compared to the TDR waveforms for the NC probe when the&#xd;
probe head was completely surrounded by water. Modeled electrostatic fields for the NC and CCRC&#xd;
CS605 TDR probes displayed a decrease in the electric potential and electric field intensity in the&#xd;
region outside of the polyolefin coating of the CCRC probe compared to the NC probe. The decrease&#xd;
v&#xd;
in potential and electric field intensity became greater when the dielectric constant of the material&#xd;
surrounding the CCRC probe increased.&#xd;
The use of a polyolefin coating on the center-conducting rod with a small section of the&#xd;
coating removed at the midsection of rod provides an effective means of extending the application of&#xd;
TDR θv and EC measurement in saline environments where standard TDR probes cannot be used.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">TDR</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Coated probes</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Geography</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Time Domain Reflectometry Measurement of Water Content and Electrical Conductivity Using a Polyolefin Coated TDR Probe</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Geography</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Environmental Studies</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>