<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T13:38:40Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/5985" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/5985</identifier><datestamp>2017-03-21T13:51:29Z</datestamp><setSpec>com_10012_9936</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9941</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="77f80e51-81d2-437a-b46b-7cb7f7d2bd4c" confidence="600">Weagant, Scott Richard</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2011-05-26T17:49:32Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2011-05-26T17:49:32Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2011-05-26T17:49:32Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/5985</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">The present elemental analysis workhorse worldwide is Inductively Coupled Plasma (ICP) Atomic Emission Spectrometry (AES) and Mass Spectrometry (MS). Due to the high power requirements, large gas consumption and the more obvious attribute, size, the ICP is tethered to the lab. Usually, samples must be collected, bottled, sometimes stabilized by acids and then shipped back to the lab for analysis (hours to days to weeks turnover rate). Due to the demand for a portable analyzer this thesis will focus on further development of microplasma devices (MPDs) for portable on-site analysis, in (near) real-time.&#xd;
Mini-In-Torch Vapourization (mini-ITV) is the sample introduction method for MPDs which removes the need for sample preparation (further necessitates portability). Mini-ITV introduces the sample into the MPD via electrothermal vapourization of a dry (water-free) nano- to micro- volume sample. Pneumatic nebulization, the commercially available ICP sample introduction method would extinguish the microplasma.&#xd;
Microplasma stability is the first issue addressed by confining the microplasma to a quartz tube (“wall-stabilized”) in hopes of a more stable MPD background emission. Once stabilized MPD conditions were found key microplasma parameters were studied including MPD power, HVac frequency, operating mode, inter-electrode distance (IED) and observation location, in hopes of improved MPD analytical performance.&#xd;
Microplasma excitation mechanism and maximum energy available in the microplasma for analyte are discussed. Some fundamental characteristics such as excitation temperature (Texc) and changes in atom/ion population with variation in some of the key MPD parameters were also determined.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">MPD</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">mini-ITV</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">On-site analysis</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Microplasmas</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Elemental analysis</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Chemistry</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Further Development of Atmospheric Pressure, Self-Igniting Microplasma Devices (MPDs) for Elemental Analysis of Liquid Microsamples Using Atomic Emission Spectrometry (AES)</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Chemistry</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>