<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-23T04:56:21Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/6238" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/6238</identifier><datestamp>2017-03-21T20:34:08Z</datestamp><setSpec>com_10012_9936</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9949</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="13d8a836-23ae-45f8-ad13-6bfdb2d65bdc" confidence="600">Schreiter, Kurt</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2011-09-02T13:57:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2011-09-02T13:57:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2011-09-02T13:57:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2011</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/6238</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Biomedical imaging requires high resolution to see the fine features of a sample and&#xd;
fast acquisition to observe live cells that move. Optical coherence tomography (OCT) is&#xd;
a powerful technique which uses optical interference for non-invasive high resolution 3D&#xd;
imaging in biological samples.&#xd;
The resolution of OCT is determined by the length over which the light used will in-&#xd;
terfere. Unfortunately, dispersion hurts the imaging resolution by broadening interference&#xd;
features. A technique called quantum-OCT (QOCT)[1] is immune to dispersion but re-&#xd;
quires entangled photon pairs. The need for entanglement drastically reduces the number&#xd;
of photons available for imaging, making QOCT too slow to be practical. Chirped-pulse&#xd;
interferometry (CPI) is also immune to dispersion. A chirped pulse is one where the fre-&#xd;
quency, or colour, of the light changes from red to blue from one end of the pulse to the&#xd;
other. CPI relies on frequency correlations created by applying different chirps to two sep-&#xd;
arate pulses. This method had the disadvantage of being limited to a single predetermined&#xd;
chirp rate, and discarded 50% of the power. However CPI has better resolution than OCT,&#xd;
automatic dispersion cancellation, and 10,000,000 times the signal strength of QOCT [13].&#xd;
A new, much more flexible and efficient method of CPI will be demonstrated by creating&#xd;
the frequency correlations entirely in a single pulse. This new method is referred to as non-&#xd;
linear chirped pulse interferometry (NL-CPI).&#xd;
The non-linear chirp required in NCPI is very difficult to produce using only conven-&#xd;
tional optics. In this thesis we document the construction and characterization of a new&#xd;
method of creating the desired chirp using a programmable pulse-shaper (PS). We build a&#xd;
PPS and then demonstrated its functionality by compressing a 105nm FWHM bandwidth&#xd;
pulse to under 17f s, near its transform limited time duration. We also show that the&#xd;
values given to the PPS for dispersion are accurate by calculating and then compensating&#xd;
the dispersion caused by various optical elements in the CPI interferometer.&#xd;
Conventional OCT systems are immune to dispersion common to both arms of the&#xd;
interferometer. Non-linear interferometers experience broadening due to this dispersion,&#xd;
making them more difficult to use with fibre based interferometers common in conventional&#xd;
OCT. We show that NL-CPI can compensate for dispersion common to both arms of the&#xd;
interferometer, making NL-CPI more appealing as a replacement for conventional OCT.&#xd;
In this thesis we experimentally implement and demonstrate a prototype setup using&#xd;
non-linear CPI for dispersion-cancelled imaging of a mirror, with a resolution comparable&#xd;
to conventional OCT systems. We then use the system to produce 2-D cross sectional&#xd;
images of a biological sample, an onion. Q-OCT has previously been used to image an&#xd;
onion[16], but required treating the onion with gold nano particles to achieve a useful&#xd;
signal. The onion we used had no special treatment. In addition our axial scanning rate&#xd;
is also 10000 times faster than Q-OCT.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Bio-imaging</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Non-linear optics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Chirped Pulse Interferomtry</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Onion</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Physics</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Optical Pulse Shaping For Chirped Pulse Interferometry And Bio-Imaging</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Physics and Astronomy</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>