<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T13:18:49Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/6323" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/6323</identifier><datestamp>2017-03-21T18:44:24Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9912</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="3eadb033-a53a-41d1-b9f6-a9dcf249d203" confidence="600">Lee, Bong-Joo</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2011-09-30T16:12:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2011-09-30T16:12:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2011-09-30T16:12:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2011-09-28</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/6323</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">This thesis evaluates performance of a non-mechanical conduit valve that was designed for the purpose of this research. The motivation came from the need for a cooling system of portable computers (e.g. laptops and netbooks). As the technology of micro-processors in portable computers advances, they will generate more heat, requiring a more effective and efficient way to cool the system. Based on this fact, a new method of heat dissipation using a single-phase liquid (i.e. water) instead of air was examined. This potentially allowed 80 times more heat dissipation, which translates to better and faster computers for the near future. &#xd;
In designing a single-phase-liquid micro-scale cooling system, various pump mechanisms and their functionalities were considered. It was concluded that a diaphragm pump design is the most effective candidate for this cooling system. The essential component when designing a diaphragm pump is a valve; however, the main issues in selecting a valve are its mechanics and required maintenance. Thus, the non-mechanical valvular conduit, which uses no moving mechanism, was studied through a combination of numerical/computational and experimental methods.&#xd;
The non-mechanical valvular conduit is a micro-channel with a complex geometry; hence, this conduit uses the principle of pressure resistance in the channel flow such that the flow is uni-directional. Through the numerical study, the valvular conduit design’s geometric dimensions were optimized. Then numerical simulations of the pumping/oscillating sequence of the valvular conduit were conducted to examine the effectiveness of the valve when placed in use for a diaphragm pump. It was found that the non-mechanical valve was 38 % more effective in the favorable direction than the opposite direction. As for the necessary heat dissipation, this conduit design demonstrates a great potential to dissipate the thermal design power (TDP) of Intel Pentium D processor (i.e. 130 [W]). During the experiments, the non-mechanical valve confirmed the numerical results. The experimental results also demonstrated that the favorable direction flow produced 244 % less pressure resistance than the opposite direction flow. &#xd;
It was concluded that the non-mechanical valvular conduit can be an effective application for diaphragm pumps in macro and micro-scale without any possibility of obstructing a mechanism.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Thermodynamics</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Computational Fluid Dynamics</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Single Phase Pump: Non-Mechanical Valvular Conduit</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Mechanical and Mechatronics Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>