<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T11:48:31Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/7281" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/7281</identifier><datestamp>2017-03-21T20:32:40Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9906</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="ce94df0e-a77c-4e25-9fbd-c9a1f49d896c" confidence="600">McLellan, Nicole</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-01-25T16:29:15Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-01-25T16:29:15Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2013-01-25T16:29:15Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2013</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/7281</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Three tiers of bench-scale experiments were conducted to evaluate the use of laboratory column&#xd;
investigations for studying the transport and removal of pathogenic microorganisms (i.e. disease causing&#xd;
viruses, bacteria and protozoa) and pathogen-surrogates (i.e. (bio)colloids) in saturated porous media&#xd;
(filtration). These experiments were used to explore the effects of individual and concurrent factors on the&#xd;
transport and removal of a suite of (bio)colloids at a range of environmentally relevant conditions typical&#xd;
of natural riverbank filtration and engineered drinking water filters. Several bench-scale column designs&#xd;
were investigated to elucidate laboratory-scale column size factors that may affect reproducibility of&#xd;
(bio)colloid passage through granular media filtration. The physical and chemical factors investigated for&#xd;
their individual and concurrent effects on the transport of a suite of (bio)colloids included: media grain&#xd;
size, media uniformity coefficient, ionic strength, and the presence of natural organic matter. The suite of&#xd;
pathogens and (bio)colloids utilized in this study included PR772 bacteriophage, Escherichia coli RS2g&#xd;
bacteria, Salmonella typhimurium bacterial pathogen, and two sizes of fluorescent polycarbonate&#xd;
microspheres (1.1 μm and 4.5 μm). In addition to S. typhimurium, pathogenic bacterial strains of E. coli&#xd;
and Pseudomonas aeruginosa were isolated and used in an experiment to investigate the effects of&#xd;
bacterial exposure to different environmental water matrices (impacted by various land-uses) on the&#xd;
transport of pathogenic bacteria. Additionally, the effects of bacterial exposure to the different water&#xd;
matrices on cell size and surface EPS composition of the suite of bacterial pathogens were investigated.&#xd;
Pathogen and (bio)colloid removal was assessed for the three experiments by plotting breakthrough&#xd;
curves and/or removal value from each trial, followed by ANOVA to determine the statistical&#xd;
significance of the effect of each parameter studied on (bio)colloid removal. The outcomes of this work&#xd;
have several implications for the use of bench-scale column studies in (bio)colloid transport&#xd;
investigations to improve the understanding of natural and engineered filter performance.&#xd;
Laboratory bench-scale experiments using replicate glass columns proved to be a useful tool in&#xd;
investigating factors that affect (bio)colloid transport in saturated porous media. In contrasts to common&#xd;
recommendations for experimental design (e.g., column diameter (D) to collector diameter (d) ratio &amp;gt; 50),&#xd;
column and collector media designs with D/d between 15 and 116 did not have a significant effect on the&#xd;
reproducibility and removal of a suite of (bio)colloids in transport investigations using varying ionic&#xd;
strengths and flow velocities representative of natural subsurface environments. Accordingly, small scale&#xd;
column studies of (bio)colloid removal by filtration that are conducted at D/d &amp;lt; 50 should not be&#xd;
universally disregarded because of wall effects concerns.&#xd;
iv&#xd;
Observations of (bio)colloid removal by granular media filtration were generally consistent with colloid&#xd;
filtration theory. Grain size, ionic strength and the presence of natural organic matter significantly&#xd;
affected the removal of a suite of (bio)colloids at values representative of natural field conditions.&#xd;
Interaction effects were also identified between the chemical factors of ionic strength and natural organic&#xd;
matter, as well as between physical media characteristics of grain size and uniformity coefficient. These&#xd;
results suggest that synergistic effects within physical and chemical factors known to effect pathogen&#xd;
transport in saturated porous media should be considered when assessing pilot- and full-scale filter&#xd;
performance demonstrations.&#xd;
Differences in removal between the suite of bacterial pathogens investigated at conditions representative&#xd;
of subsurface filtration were small (&amp;lt;0.5 log), suggesting that nuances between the removal of various&#xd;
strains of bacteria that are present at the micro-scale may not be substantial at the macro- or field-scale.&#xd;
The effects of bacterial EPS on (bio)colloid transport may be more important in environments with&#xd;
profuse biofilm formation (unlike the “clean-bed” environments used in this study). Established and&#xd;
standardised methods for EPS extraction and characterization for a range of applications are necessary to&#xd;
improve our understanding of bacterial EPS production, and the effects of these compounds in a range of&#xd;
saturated porous media environments. A conceptual model was developed to encompass the current state&#xd;
of knowledge on bacterial EPS effects on bacterial removal and the results presented herein.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Factors Affecting the Transport of Pathogens &amp;amp; Pathogen Surrogates in Saturated Porous Media: Implications for Natural &amp;amp; Engineered Drinking Water Filters</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="comment" qualifier="hidden" lang="en">This is the most recent version of my thesis. January 23,2013.</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Civil Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Civil and Environmental Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>