<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T15:24:43Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/7559" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/7559</identifier><datestamp>2017-03-21T14:54:11Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9908</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="bea5bdf7-22e7-4bb9-ace9-876085d88d40" confidence="600">Khalifa, Tarek</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-05-23T15:37:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-05-23T15:37:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2013-05-23T15:37:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2013-05-21</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/7559</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Utility companies (electricity, gas, and water suppliers), governments, and&#xd;
researchers recognize an urgent need to deploy communication-based systems to&#xd;
automate data collection from smart meters and sensors, known as Smart Metering&#xd;
Infrastructure (SMI) or Automatic Meter Reading (AMR). A smart metering system&#xd;
is envisaged to bring tremendous benefits to customers, utilities, and&#xd;
governments. The advantages include reducing peak demand for energy, supporting&#xd;
the time-of-use concept for billing, enabling customers to make informed&#xd;
decisions, and performing effective load management, to name a few.&#xd;
&#xd;
A key element in an SMI is communications between meters and utility servers.&#xd;
However, the mass deployment of metering devices in the grid calls for studying&#xd;
the scalability of communication protocols. SMI is characterized by the&#xd;
deployment of a large number of small Internet Protocol (IP) devices sending&#xd;
small packets at a low rate to a central server. Although the individual&#xd;
devices generate data at a low rate, the collective traffic produced is&#xd;
significant and is disruptive to network communication functionality. This&#xd;
research work focuses on the scalability of the transport layer&#xd;
functionalities. The TCP congestion control mechanism, in particular, would be&#xd;
ineffective for the traffic of smart meters because a large volume of data&#xd;
comes from a large number of individual sources. This situation makes the TCP&#xd;
congestion control mechanism unable to lower the transmission rate even when&#xd;
congestion occurs. The consequences are a high loss rate for metered data and&#xd;
degraded throughput for competing traffic in the smart metering network.&#xd;
&#xd;
&#xd;
To enhance the performance of TCP in a smart metering infrastructure (SMI), we&#xd;
introduce a novel TCP-based scheme, called Split- and Aggregated-TCP (SA-TCP).&#xd;
This scheme is based on the idea of upgrading intermediate devices in SMI&#xd;
(known in the industry as regional collectors) to offer the service of&#xd;
aggregating the TCP connections. An SA-TCP aggregator collects data packets&#xd;
from the smart meters of its region over separate TCP connections; then it&#xd;
reliably forwards the data over another TCP connection to the utility server.&#xd;
The proposed split and aggregated scheme provides a better response to traffic&#xd;
conditions and, most importantly, makes the TCP congestion control and flow&#xd;
control mechanisms effective. Supported by extensive ns-2 simulations, we show&#xd;
the effectiveness of the SA-TCP approach to mitigating the problems in terms of&#xd;
the throughput and packet loss rate performance metrics.&#xd;
&#xd;
&#xd;
A full mathematical model of SA-TCP is provided. The model is highly accurate&#xd;
and flexible in predicting the behaviour of the two stages, separately and&#xd;
combined, of the SA-TCP scheme in terms of throughput, packet loss rate and&#xd;
end-to-end delay. Considering the two stages of the scheme, the modelling&#xd;
approach uses Markovian models to represent smart meters in the first stage and&#xd;
SA-TCP aggregators in the second. Then, the approach studies the interaction of&#xd;
smart meters and SA-TCP aggregators with the network by means of standard&#xd;
queuing models. The ns-2 simulations validate the math model results.&#xd;
&#xd;
A comprehensive performance analysis of the SA-TCP scheme is performed. It&#xd;
studies the impact of varying various parameters on the scheme, including the&#xd;
impact of network link capacity, buffering capacity of those RCs that act as&#xd;
SA-TCP aggregators, propagation delay between the meters and the utility&#xd;
server, and finally, the number of SA-TCP aggregators. The performance results&#xd;
show that adjusting those parameters makes it possible to further enhance&#xd;
congestion control in SMI. Therefore, this thesis also formulates an&#xd;
optimization model to achieve better TCP performance and ensures satisfactory&#xd;
performance results, such as a minimal loss rate and acceptable end-to-end&#xd;
delay. The optimization model also considers minimizing the SA-TCP scheme&#xd;
deployment cost by balancing the number of SA-TCP aggregators and the link&#xd;
bandwidth, while still satisfying performance requirements.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">smart power grid</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">communication</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">transmission control protocol</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">smart meters</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">smart metering infrastructure</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Design and Analysis of a Novel Split and Aggregated Transmission Control Protocol for Smart Metering Infrastructure</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Doctoral Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Electrical and Computer Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Doctor of Philosophy</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>