<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T10:22:04Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/7573" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/7573</identifier><datestamp>2017-03-21T20:44:16Z</datestamp><setSpec>com_10012_9924</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9930</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="f41931ae-fec3-426d-be1c-720e99dd81ef" confidence="600">Gao, Xiang</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2013-05-23T19:50:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2013-05-23T19:50:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2013-05-23T19:50:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2013</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/7573</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Heating, Ventilation, and Air Conditioning (HVAC) accounts for about half of the energy&#xd;
consumption in buildings. HVAC energy consumption can be reduced by changing the&#xd;
indoor air temperature setpoint, but changing the setpoint too aggressively can overly&#xd;
reduce user comfort. We have therefore designed and implemented SPOT: a Smart Per-&#xd;
sonalized O ce Thermal control system that balances energy conservation with personal&#xd;
thermal comfort in an o ce environment. SPOT relies on a new model for personal ther-&#xd;
mal comfort that we call the Predicted Personal Vote model. This model quantitatively&#xd;
predicts human comfort based on a set of underlying measurable environmental and per-&#xd;
sonal parameters. SPOT uses a set of sensors, including a Microsoft Kinect, to measure&#xd;
the parameters underlying the PPV model, then controls heating and cooling elements&#xd;
to dynamically adjust indoor temperature to maintain comfort. Based on a deployment&#xd;
of SPOT in a real o ce environment, we  nd that SPOT can accurately maintain per-&#xd;
sonal comfort despite environmental &#xd;
uctuations and allows a worker to balance personal&#xd;
comfort with energy use.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Thermal Control</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Computer Science</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">SPOT: A Smart Personalized Office Thermal Control System</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">School of Computer Science</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Mathematics</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>