<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T19:47:06Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/8292" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/8292</identifier><datestamp>2017-03-21T14:53:57Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9912</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="cfa94299-2348-4c57-8f0b-35dcf4d4abf9" confidence="600">Chan, WenYen</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-03-13T13:42:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2015-05-02T05:30:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2014-03-13</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2014-02-28</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/8292</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">The objective of this thesis is the design and realization of a higher efficiency air source heat pump. The improved pump’s operating cost must rival the cost of heating with natural gas, while incurring a minimal increase in the capital cost of the pump. A COP greater than 4 at –15C ambient is needed to achieve this goal. During winter season testing a COP of 4.25 +/- 0.11 was observed. This tracks well with a predicted COP of 4.4 and also against a commercial system with a claimed COP between 2.1 and 3.0.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="embargoterms" lang="en">1 year</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">heat pump</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">MIXED PHASE COMPRESSION HIGH EFFICIENCY HEAT PUMP</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="comment" qualifier="hidden" lang="en">title page edited, numbering centered, table of contents edited. newer PDF conversion used. this should result in a smaller file size.&#xd;
&#xd;
sorry about the edits. not sure how I missed them.</dim:field>
   <dim:field mdschema="dc" element="pending">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Mechanical and Mechatronics Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>