<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T07:23:40Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/8906" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/8906</identifier><datestamp>2017-03-21T17:26:44Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9912</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" authority="e70fc037-d965-4d6a-86eb-f7b447670a40" confidence="600">Roohparvarzadeh, Sogol</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2014-10-17T19:43:25Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2014-10-17T19:43:25Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2014-10-17</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2014</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/8906</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Successful commercialization of polymer electrolyte membrane (PEM) fuel cells is highly&#xd;
dependant on performance of the membrane electrode assembly (MEA). The performance&#xd;
of the gas diffusion layer (GDL) of the MEA is highly influenced by applied compressive&#xd;
load. Compression of the GDL changes its porosity and microstructure, which will conse-&#xd;
quently change the physical properties of the GDL. Hence to improve the properties of the&#xd;
GDL, understanding its compressive behaviour is crucial.&#xd;
In the present study, the compressive behaviour of the GDL is characterized by per-&#xd;
forming a series of compression tests using a compression apparatus. The compressive test&#xd;
is first performed on an untreated carbon paper by measuring its thickness as a function of&#xd;
compressive load at room temperature. The obtained results are analyzed and presented&#xd;
in a compressive stress-strain curve. The compressive stress-strain curve of the GDL is&#xd;
divided into 3 distinct regions. The first region represents the stress-strain behaviour at&#xd;
very low stress values. In this region, the compressive strain of the GDL increases rapidly&#xd;
and linearly with the applied stress. In the second region, the compressive strain increases&#xd;
less rapidly and non-linearly with applied stress. In the last region, the compressive stress-&#xd;
strain behaviour becomes linear again, but the strain increases at a lower rate. Analysis&#xd;
of the SEM images for both compressed and uncompressed GDL samples suggest that&#xd;
the stress-strain behaviour of the GDL in the first two regions is induced by the surface&#xd;
roughness and local thickness variations.&#xd;
The compressive behaviour of the GDL is further analyzed by investigating the effect of&#xd;
temperature, relative humidity, and hydrophobic treatment. The compressive stress-strain&#xd;
curves obtained at temperatures of 25 ◦ C, 45 ◦ C, 65 ◦ C, and 85 ◦ C are almost identical within&#xd;
the experimental margin of error, which suggests that fuel cell’s operating temperature has&#xd;
no appreciable effect on the compressibility of the GDL. The compressive stress-strain&#xd;
curve obtained from compressive test at humidified environment shows a higher change&#xd;
in strain in the second region of the curve. The study on the effect of Polytetrafluo-&#xd;
roethylene (PTFE) coating on compressibility and pore distribution shows that increase&#xd;
in PTFE content decreases the overall pore volume of the GDL and hence decreases the&#xd;
compressibility.&#xd;
At last, the effect of cyclic loading is studied by measuring the thickness of GDL&#xd;
samples during 2500 loading/unloading cycles. The strain of the GDL samples increases&#xd;
by 50% after the samples undergo 2500 cycles of compression. The effect of unloading&#xd;
was further investigated by measuring the thickness of the sample as a function of applied&#xd;
compressive load while loading the sample by compression pressures of up to 3.5MPa and then unloading the sample to zero MPa for seven cycles. It is found that the structure&#xd;
of the GDL degrades significantly under compression cycles. This study concludes that&#xd;
the compressive behaviour of the GDL under cyclic compression is a major drawback and&#xd;
without further improvements, the required durability will not be achieved.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Polymer electrolyte membrane (PEM) fuel cells</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Gas diffusion layer (GDL)</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Compression</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Compressive stress-strain</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Cyclic compression</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="program" lang="en">Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Experimental Characterization of the Compressive Behaviour of Gas Diffusion Layers in PEM Fuel Cells</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Mechanical and Mechatronics Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>