<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T01:50:44Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/896" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/896</identifier><datestamp>2017-03-21T21:42:21Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9912</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en" authority="b4ec3d72-225e-48d7-a51f-50144e798972" confidence="600">Hossain, Md Rakib</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-08-22T14:00:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-08-22T14:00:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/896</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Forced air cooling of electronic packages is enhanced through the use of extended  surfaces or heat sinks that reduce boundary resistance allowing heat generating devices to operate at lower temperatures, thereby improving reliability.   Unfortunately, the clearance zones or bypass regions surrounding the heat sink,  channel some of the cooling air mass away from the heat sink,  making it difficult to accurately estimate thermal performance.    The design of an &amp;quot;optimized&amp;quot; heat sink requires a complete  knowledge of all thermal resistances between the heat source and  the ambient air, therefore, it is imperative that the boundary  resistance is properly characterized, since it is typically the  controlling resistance in the path.   Existing models are difficult  to incorporate into optimization routines because they do not  provide a means of predicting flow bypass based on information at  hand, such as heat sink geometry or approach velocity.    &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;  A procedure is presented that allows the simultaneous optimization  of heat sink design parameters based on a minimization of the  entropy generation associated with thermal resistance and fluid  pressure drop.   All relevant design parameters such as geometric  parameters of a heat sink, source and bypass configurations, heat  dissipation, material properties and flow conditions can be  simultaneously optimized to characterize a heat sink that  minimizes entropy generation and in turn results in a minimum  operating temperature of an electronic component.    &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;  An analytical model for predicting air flow and pressure drop  across the heat sink is developed by applying conservation of mass  and momentum over the bypass regions and in the flow channels  established between the fins of the heat sink.   The model is  applicable for the entire laminar flow range and any type of  bypass (side, top or side and top both) or fully shrouded  configurations.   During the development of the model, the flow was  assumed to be steady, laminar, developing flow.   The model is also  correlated to a simple equation within 8% confidence level  for an easy implementation into the entropy generation  minimization procedure.   The influence of all the resistances to  heat transfer associated with a heat sink are studied, and an  order of magnitude analysis is carried out to include only the  influential resistances in the thermal resistance model.   Spreading  and material resistances due to the geometry of the base plate,  conduction and convection resistances associated with the fins of  the heat sink and convection resistance of the wetted surfaces of  the base plate are considered for the development of a thermal  resistance model.   The thermal resistance and pressure drop model  are shown to be in good agreement with the experimental data over  a wide range of flow conditions, heat sink geometries, bypass  configurations and power levels, typical of many applications  found in microelectronics and related fields.   Data published in  the open literature are also used to show the flexibility of the  models to simulate a variety of applications.    &amp;lt;br /&amp;gt;&amp;lt;br /&amp;gt;  The proposed thermal resistance and pressure drop model are  successfully used in the entropy generation minimization procedure  to design a heat sink with bypass for optimum dimensions and  performance.   A sensitivity analysis is also carried out to check  the influence of bypass configurations, power levels, heat sink  materials and the coverage ratio on the optimum dimensions and  performance of a heat sink and it is found that any change in  these parameters results in a change in the optimized heat sink  dimensions and flow conditions associated with the application for  optimal heat sink performance.</dim:field>
   <dim:field mdschema="dc" element="format" lang="en">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">1677227 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en">Copyright: 2006, &#xd;
  HOSSAIN, MD RAKIB. All rights reserved.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Heat Sinks</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Optimization</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Flow Bypass</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Pressure Drop</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Heat Transfer</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Electronic Packages</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Entropy Generation Minimization</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Optimization of Heat Sinks with Flow Bypass Using Entropy Generation Minimization</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Master Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Mechanical Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Master of Applied Science</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>