<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-22T13:12:42Z</responseDate><request verb="GetRecord" identifier="oai:uwspace.uwaterloo.ca:10012/934" metadataPrefix="dim">https://dspacemainprd01.lib.uwaterloo.ca/server/oai/request</request><GetRecord><record><header><identifier>oai:uwspace.uwaterloo.ca:10012/934</identifier><datestamp>2017-03-21T14:59:46Z</datestamp><setSpec>com_10012_9900</setSpec><setSpec>com_10012_1</setSpec><setSpec>col_10012_9914</setSpec><setSpec>col_10012_6</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en" authority="57e38c79-ac5e-4f70-9887-efe5b0ad63ea" confidence="600">Rasheed, Sarbast</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-08-22T13:50:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-08-22T13:50:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10012/934</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">EMG signal decomposition is the process of resolving a composite EMG signal into its  constituent motor unit potential trains (classes) and it can be configured as a classification  problem.   An EMG signal detected by the tip of an inserted needle electrode is the superposition  of the individual electrical contributions of the different motor units that are active, during  a muscle contraction, and background interference.      
&amp;lt;BR&amp;gt;This thesis addresses the process of EMG signal decomposition by developing an interactive  classification system, which uses multiple classifier fusion techniques in order to achieve  improved classification performance.   The developed system combines heterogeneous sets of base classifier ensembles of different kinds and employs either a one level classifier fusion scheme or a hybrid classifier fusion approach.      
&amp;lt;BR&amp;gt;The hybrid classifier fusion approach is applied as a two-stage combination process that  uses a new aggregator module which consists of two combiners: the first at the abstract level of  classifier fusion and the other at the measurement level of classifier fusion such that it uses both combiners in a complementary manner.   Both combiners may be either data independent or the first combiner data independent and the second data dependent.   For the purpose of experimentation, we used as first combiner the majority voting scheme, while we used as the second combiner one of the fixed combination rules behaving as a data independent combiner or the fuzzy integral with the lambda-fuzzy measure as an implicit data dependent combiner.      
&amp;lt;BR&amp;gt;Once the set of motor unit potential trains are generated by the classifier fusion system,  the firing pattern consistency statistics for each train are calculated to detect classification  errors in an adaptive fashion.   This firing pattern analysis allows the algorithm to modify the threshold of assertion required for assignment of a motor unit potential classification individually for each train based on an expectation of erroneous assignments.      
&amp;lt;BR&amp;gt;The classifier ensembles consist of a set of different versions of the Certainty classifier,  a set of classifiers based on the nearest neighbour decision rule: the fuzzy &amp;lt;em&amp;gt;k&amp;lt;/em&amp;gt;-NN and the  adaptive fuzzy &amp;lt;em&amp;gt;k&amp;lt;/em&amp;gt;-NN classifiers, and a set of classifiers that use a correlation measure as  an estimation of the degree of similarity between a pattern and a class template: the matched  template filter classifiers and its adaptive counterpart.   The base classifiers, besides being  of different kinds, utilize different types of features and their performances were investigated  using both real and simulated EMG signals of different complexities.   The feature sets extracted  include time-domain data, first- and second-order discrete derivative data, and wavelet-domain data.      
&amp;lt;BR&amp;gt;Following the so-called &amp;lt;em&amp;gt;overproduce and choose&amp;lt;/em&amp;gt; strategy to classifier ensemble combination, the developed system allows the construction of a large set of candidate base  classifiers and then chooses, from the base classifiers pool, subsets of specified number of  classifiers to form candidate classifier ensembles.   The system then selects the classifier  ensemble having the maximum degree of agreement by exploiting a diversity measure for designing  classifier teams.   The kappa statistic is used as the diversity measure to estimate the level  of agreement between the base classifier outputs, i.  e.  , to measure the degree of decision similarity  between the base classifiers.   This mechanism of choosing the team&amp;apos;s classifiers based on assessing  the classifier agreement throughout all the trains and the unassigned category is applied during the one level classifier fusion scheme and the first combiner in the hybrid classifier fusion  approach.   For the second combiner in the hybrid classifier fusion approach, we choose team  classifiers also based on kappa statistics but by assessing the classifiers agreement only across  the unassigned category and choose those base classifiers having the minimum agreement.      
&amp;lt;BR&amp;gt;Performance of the developed classifier fusion system, in both of its variants, i.  e.  , the one level scheme and the hybrid approach was evaluated using synthetic simulated signals of known properties and real signals and then compared it with the performance of the constituent base classifiers.   Across the EMG signal data sets used, the hybrid approach had better average classification performance overall, specially in terms of reducing the number of classification errors.</dim:field>
   <dim:field mdschema="dc" element="format" lang="en">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">2998120 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en">University of Waterloo</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en">Copyright: 2006, 
  Rasheed, Sarbast. All rights reserved.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Systems Design</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">Combination of multiple classifiers</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">classifier ensembles</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">motor unit potential classification</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">motor unit firing patterns</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">base classifiers</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">one level classifier fusion</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">hybrid classifier fusion</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">diversity measure</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">classifier agreement.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">A Multiclassifier Approach to Motor Unit Potential Classification for EMG Signal Decomposition</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Doctoral Thesis</dim:field>
   <dim:field mdschema="dc" element="pending" lang="en">false</dim:field>
   <dim:field mdschema="uws-etd" element="degree" qualifier="department" lang="en">Systems Design Engineering</dim:field>
   <dim:field mdschema="uws-etd" element="degree" lang="en">Doctor of Philosophy</dim:field>
   <dim:field mdschema="uws" element="typeOfResource" lang="en">Text</dim:field>
   <dim:field mdschema="uws" element="peerReviewStatus" lang="en">Unreviewed</dim:field>
   <dim:field mdschema="uws" element="scholarLevel" lang="en">Graduate</dim:field>
   <dim:field mdschema="others" element="access-status">open.access</dim:field>